Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: https://tedebc.ufma.br/jspui/handle/tede/6433
Tipo do documento: Dissertação
Título: Sistemas de Climatização como alternativa sustentável para implementação de ar-condicionado em âmbito hospitalar na cidade de São Luís-MA
Título(s) alternativo(s): Air conditioning systems as a sustainable alternative for implementing air conditioning in hospitals in the city of São Luís, Maranhão
Autor: MAIA, Thiago dos Santos 
Primeiro orientador: COELHO, Paulo Henrique da Silva Leite
Primeiro coorientador: BERTOLDO JUNIOR, Jorge
Primeiro membro da banca: COELHO, Paulo Henrique da Silva Leite Coelho
Segundo membro da banca: BERTOLDO JUNIOR, Jorge
Terceiro membro da banca: FIGUEROA, Jaiver Efrén Jaimes
Quarto membro da banca: FIGUEIREDO , Alisson Augusto Azevedo
Resumo: No âmbito hospitalar, os sistemas de climatização podem garantir o conforto térmico e a qualidade do ar, ambos benéficos para a saúde dos pacientes e para as atividades desempenhadas pela equipe assistencial. Esta pesquisa tem como objetivo geral investigar a viabilidade de implementação de um sistema de climatização sustentável, baseado em energia renovável, para a UTI do HUUFMA, em comparação com um sistema convencional de compressão de vapor mediante a simulação energética de cada proposta. Trata-se de uma pesquisa aplicada, de abordagem quantitativa e exploratória, que inicialmente identificou a caracterização das propriedades construtivas, termohigrométricas e o posicionamento solar da UTI em relação ao edifício. Para tanto, posteriormente realizou-se o cálculo da carga térmica e a análise energética dos dois sistemas propostos. A simulação de ambos os sistemas considerou a eficiência energética, a demanda de energia e o impacto ambiental. Os resultados demonstraram que o cálculo da carga térmica total foi de 67,86 kW (19,3 TR), que corresponde ao potencial de demanda de remoção de calor necessário para o funcionamento da UTI. A partir dessa demanda, a simulação energética do chiller por compressão de vapor indicou um consumo de 732,96 kWh/dia, com uma capacidade de refrigeração de 87,92 kW (ou 25 TR) e um coeficiente de performance de 2,88 para um funcionamento de 24 horas. Enquanto a simulação energética de um chiller por absorção foi de 246.093,80 kWh/ano, com uma capacidade de refrigeração de 88 kW (ou 25 TR) e um coeficiente de performance de 0,70 para um funcionamento de 6 horas. Conclui-se que o sistema de climatização chiller por absorção tem potencial para substituir o sistema de compressão de vapor em períodos de alta demanda por resfriamento, o que contribui para a redução da emissão de CO2 por sua atividade.
Abstract: In the hospital setting, air conditioning systems can ensure thermal comfort and air quality, both beneficial for the health of patients and for the activities carried out by the healthcare team. The general objective of this research is to investigate the feasibility of implementing a sustainable air conditioning system, based on renewable energy, for the ICU at HUUFMA, in comparison with a conventional vapor compression system, through the energy simulation of each proposal. This is an applied research with a quantitative and exploratory approach, which initially identified the characterization of the constructive, thermohygrometric properties, and the solar positioning of the ICU in relation to the building. Subsequently, the thermal load calculation and energy analysis of both proposed systems were performed. The simulation of both systems considered energy efficiency, energy demand, and environmental impact. The results showed that the total thermal load calculation was 67.86 kW (19.3 TR), corresponding to the heat removal demand required for the ICU operation. Based on this demand, the energy simulation of the vapor compression chiller indicated a consumption of 732.96 kWh/day, with a refrigeration capacity of 87.92 kW (or 25 TR) and a coefficient of performance of 2.88 for a 24-hour operation. Meanwhile, the energy simulation of an absorption chiller was 246,093.80 kWh/year, with a refrigeration capacity of 88 kW (or 25 TR) and a coefficient of performance of 0.70 for a 6-hour operation. It is concluded that the absorption chiller air conditioning system has the potential to replace the vapor compression system during periods of high cooling demand, contributing to a reduction in CO2 emissions due to its activity.
Palavras-chave: energia solar;
hospital;
simulação energética;
sustentabilidade.
solar energy;
hospital;
energy simulation;
sustainability.
Área(s) do CNPq: Engenharia Térmica
Engenharias
Idioma: por
País: Brasil
Instituição: Universidade Federal do Maranhão
Sigla da instituição: UFMA
Departamento: DEPARTAMENTO DE TECNOLOGIA QUÍMICA/CCET
Programa: PROGRAMA DE PÓS-GRADUAÇÃO EM ENERGIA E AMBIENTE/CCET
Citação: MAIA, Thiago dos Santos. Sistemas de Climatização como alternativa sustentável para implementação de ar-condicionado em âmbito hospitalar na cidade de São Luís-MA. 2025. 101 f. Dissertação (Programa de Pós-Graduação em Energia e Ambiente/CCET) - Universidade Federal do Maranhão, São Luís, 2025.
Tipo de acesso: Acesso Aberto
URI: https://tedebc.ufma.br/jspui/handle/tede/6433
Data de defesa: 10-Fev-2025
Aparece nas coleções:DISSERTAÇÃO DE MESTRADO - PROGRAMA DE PÓS-GRADUAÇÃO EM ENERGIA E AMBIENTE

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
THIAGO_MAIA.pdfDissertação de Mestrado2,1 MBAdobe PDFBaixar/Abrir Pré-Visualizar


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.