Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: https://tedebc.ufma.br/jspui/handle/tede/5996
Registro completo de metadados
Campo DCValorIdioma
dc.creatorPAULO, Thiago Vieira-
dc.creator.Latteshttp://lattes.cnpq.br/4214295315807089por
dc.contributor.advisor1NASCIMENTO, Ulisses Magalhaes-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/3964114535425211por
dc.contributor.advisor-co1PINHEIRO, Helilma de Andrea-
dc.contributor.advisor-co1Latteshttp://lattes.cnpq.br/5215098725391980por
dc.contributor.referee1NASCIMENTO, Ulisses Magalhaes-
dc.contributor.referee1Latteshttp://lattes.cnpq.br/3964114535425211por
dc.contributor.referee2OLIVEIRA, Regina Maria Mendes-
dc.contributor.referee2Latteshttp://lattes.cnpq.br/0972206150174877por
dc.contributor.referee3SOUSA, Janyeid Karla Castro-
dc.date.accessioned2025-03-14T15:02:08Z-
dc.date.issued2025-02-13-
dc.identifier.citationPAULO, Thiago Vieira. Sensor eletroquímico à base de nanotubos de carbono e nanopartículas de óxido de ferro para determinação simultânea de hidroquinona e resorcinol em águas superficiais. 2025. 69 f. Dissertação( Programa de Pós-graduação em Desenvolvimento e Meio Ambiente) - Universidade Federal do Maranhão, São Luís, 2025.por
dc.identifier.urihttps://tedebc.ufma.br/jspui/handle/tede/5996-
dc.description.resumoHidroquinona (HQ, 1,4-di-hidroxibenzeno) e resorcinol (RS, 1,3-di-hidroxibenzeno) são derivados do benzeno extensivamente empregados em atividades agrícolas, indústrias química e farmacêutica. Além disso, são considerados microcontaminantes emergentes devido à sua persistente toxicidade para plantas e animais, mesmo em concentrações extremamente baixas. O presente trabalho propõe um sensor eletroquímico baseado em eletrodo de carbono vítreo modificado com nanotubos de carbono de paredes múltiplas funcionalizados com grupos carboxila e nanopartículas de óxido de ferro (ECV/NTCPM-COOH/Fe2O3) para determinação simultânea de hidroquinona (HQ) e resorcinol (RS) em amostras de águas superficiais. As propriedades físico-química dos materiais (Fe2O3, NTCPM-COOH e NTCPM-COOH/Fe2O3) foram caracterizadas por microscopia eletrônica de varredura (MEV), espectroscopia de infravermelho com transformada de Fourier (FT-IR) e difração de raios X (DRX). As propriedades eletroquímicas do sensor foram avaliadas utilizando técnicas de voltametria cíclica (CV) e voltametria de pulso diferencial (DPV). O sensor ECV/NTCPM-COOH/Fe2O3 apresentou um aumento das correntes de pico voltamétricos de HQ e RS em comparação ao ECV não modificado e ao ECV modificado com os materiais individuais (ECV/NTCPMCOOH e ECV/Fe2O3). Sob condições otimizadas, o sensor proposto apresentou um excelente desempenho para a determinação simultânea dos analitos, mostrando um comportamento linear na faixa de 10 a 150 μM para HQ e de 15 a 150 μM para RS. Os limites de detecção (LODs) calculados para HQ e RS foram 0,49 μM e 0,70 μM, respectivamente. Além disso, bons resultados em termos de precisão, exatidão e estabilidade foram observados. O sensor proposto foi aplicado com sucesso para determinação de HQ e RS em água de rio, com valores de recuperação satisfatórios. Os resultados indicam do ponto de vista analítico e estatístico, que o sensor proposto é adequado como um método alternativo para realizar a determinação de HQ e RS em amostras de água.por
dc.description.abstractHydroquinone (HQ, 1,4-dihydroxybenzene) and resorcinol (RS, 1,3-dihydroxybenzene) are benzene derivatives extensively used in agricultural activities, chemical and pharmaceutical industries. Furthermore, they are considered emerging microcontaminants due to their persistent toxicity to plants and animals, even at extremely low concentrations. This work proposes an electrochemical sensor based on a glassy carbon electrode modified with multiwalled carbon nanotubes functionalized with carboxyl groups and iron oxide nanoparticles (GCE/MWCNT-COOH/Fe2O3) for simultaneous determination of hydroquinone (HQ) and resorcinol (RS) in surface water samples. The physicochemical properties of the materials (Fe2O3, MWCNT-COOH and MWCNT-COOH/Fe2O3) were characterized by scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FT-IR) and X-ray diffraction (XRD). The electrochemical properties of the sensor were evaluated using cyclic voltammetry (CV) and differential pulse voltammetry (DPV) techniques. The GCE/MWCNTCOOH/Fe2O3 sensor showed an increase in the voltammetric peak currents of HQ and RS compared to the unmodified GCE and the GCE modified with the individual materials (GCE/MWCNT-COOH and GCE/Fe2O3). Under optimized conditions, the proposed sensor showed an excellent performance for the simultaneous determination of the analytes, showing a linear behavior in the range of 10 to 150 μM for HQ and 15 to 150 μM for RS. The calculated limits of detection (LODs) for HQ and RS were 0.49 μM and 0.70 μM, respectively. Furthermore, good results in terms of precision, accuracy, and stability were observed. The proposed sensor was successfully applied for the determination of HQ and RS in river water, with satisfactory recovery values. The results indicate from an analytical and statistical point of view that the proposed sensor is suitable as an alternative method to perform the determination of HQ and RS in water samples.eng
dc.description.provenanceSubmitted by Maria Aparecida (cidazen@gmail.com) on 2025-03-14T15:02:08Z No. of bitstreams: 1 THIAGO VIEIRA PAULO.pdf: 1459484 bytes, checksum: ca554a514cc48664d56eaa5e11b71850 (MD5)eng
dc.description.provenanceMade available in DSpace on 2025-03-14T15:02:08Z (GMT). No. of bitstreams: 1 THIAGO VIEIRA PAULO.pdf: 1459484 bytes, checksum: ca554a514cc48664d56eaa5e11b71850 (MD5) Previous issue date: 2025-02-13eng
dc.formatapplication/pdf*
dc.languageporpor
dc.publisherUniversidade Federal do Maranhãopor
dc.publisher.departmentCOORDENAÇÃO DO CURSO DE QUÍMICA INDUSTRIAL/CCETpor
dc.publisher.countryBrasilpor
dc.publisher.initialsUFMApor
dc.publisher.programPROGRAMA DE PÓS-GRADUAÇÃO EM CIÊNCIA E TECNOLOGIA AMBIENTALpor
dc.rightsAcesso Abertopor
dc.subjectNanopartículas de óxido de ferro;por
dc.subjectnanotubos de carbono;por
dc.subjecteletrodo modificado;por
dc.subjecthidroquinona;por
dc.subjectIron oxide nanoparticles;eng
dc.subjectcarbon nanotubes;eng
dc.subjectmodified electrode;eng
dc.subjecthydroquinone;eng
dc.subjectresorcinoleng
dc.subjectresorcinolpor
dc.subject.cnpqEvolução, Sistemática e Ecologia Químicapor
dc.titleSENSOR ELETROQUÍMICO À BASE DE NANOTUBOS DE CARBONO E NANOPARTÍCULAS DE ÓXIDO DE FERRO PARA DETERMINAÇÃO SIMULTÂNEA DE HIDROQUINONA E RESORCINOL EM ÁGUAS SUPERFICIAISpor
dc.title.alternativeELECTROCHEMICAL SENSOR BASED ON CARBON NANOTUBES AND IRON OXIDE NANOPARTICLES FOR SIMULTANEOUS SIMULTANEOUS DETERMINATION OF HYDROQUINONE AND RESORCINOL IN SURFACE WATEReng
dc.typeDissertaçãopor
Aparece nas coleções:DISSERTAÇÃO DE MESTRADO - PROGRAMA DE PÓS-GRADUAÇÃO EM CIÊNCIA E TECNOLOGIA AMBIENTAL

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
THIAGO VIEIRA PAULO.pdfDissertação de Mestrado1,43 MBAdobe PDFBaixar/Abrir Pré-Visualizar


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.